Get a Quote
Social Media

How does a reefer (refrigerated) container work?

Last updated:

Short Answer — Reefer Container

A reefer container is an insulated container that cools or heats air with the electric refrigeration unit in its front wall and passes this air under the cargo through T-shaped floor channels, keeping the internal temperature at the set value. The unit runs on plug-in power on board ship and at the terminal, and on a diesel generator (genset) on the road; temperature, humidity and ventilation settings are recorded in the controller.

What parts does a reefer container consist of?

A reefer consists of an insulated box and a refrigeration machine built into the front wall. The body is insulated with polyurethane foam filled between two metal skins; the inner surface is easy-to-clean stainless steel or aluminium. The machinery section contains the compressor, condenser, evaporator, fans and a microprocessor controller. Common units operate roughly between −30 °C and +30 °C: the same container can be set below −18 °C for frozen meat or to about +13 °C for bananas. Because of the insulation, the internal dimensions are smaller than those of a dry container; the figures are in the container types and dimensions entry.

How does the cold air circulate through the cargo?

The fans pass the air through the evaporator and push it into the floor. The floor consists of aluminium T-profiles; the air travels along these channels towards the door, rises between pallets and cartons and returns to the machine across the ceiling. This circulation makes three rules mandatory:

  • The cargo must not exceed the red line (maximum load height) on the side wall; space is left at the top for the return air.
  • Any uncovered part of the floor must be covered with cardboard or boards. Otherwise the air escapes by the easiest route and part of the cargo warms up.
  • A reefer is designed to maintain the temperature of the cargo, not to cool it. The product must be loaded already brought to the target temperature (pre-cooled).

How are temperature, humidity and ventilation set?

SettingWhat is it for?Example
Set temperatureThe carriage temperature of the productFrozen food −18 °C and below; for fresh produce around 0 °C for apples, around +13 °C for bananas
Fresh air (vent)Removes the CO₂ and ethylene that build up from the respiration of fruit and vegetablesOpening in m³/hour; closed for frozen cargo
Humidity controlPrevents the product from drying out or excess moistureRelative humidity target (%)
Controlled atmosphereLowers oxygen to slow ripeningProducts on long voyages such as avocados and bananas

The settings are stated in the booking and on the bill of lading; the shipping line prepares the container according to these values. A wrong vent setting can spoil fruit even if the temperature is correct.

Where does the power come from?

  • Terminal and ship: The container is plugged into a reefer socket; units generally run on 380–460 V three-phase power. At the terminal, plugging in, monitoring and electricity may be charged separately. Terminal operations are explained in the container terminal handling entry.
  • Road and rail: A diesel generator, i.e. a genset, is used, either clipped onto the front of the container (clip-on) or mounted under the chassis (underslung). Fuel is planned according to the journey and possible waiting time.
  • Power interruption: A well-insulated reefer maintains the temperature for a while during a short interruption; however, the interruption is logged and may become the subject of a claim by the consignee.

Pre-shipment checks and data recording

  1. PTI (Pre-Trip Inspection): The shipping line or depot tests the unit's cooling, heating and sensors; a clean container that has passed PTI is released.
  2. Pre-cooling: The product is brought to the target temperature in a cold store. The container itself is generally not pre-cooled unless it is connected directly to a cold tunnel; warm, humid air entering through the open door condenses on the inner surfaces.
  3. Loading: The unit is switched off while the doors are open and switched on after the door has been closed and sealed.
  4. Recording: The controller logs supply and return air temperatures, alarms and door openings. For products such as pharmaceuticals, independent temperature data loggers are also placed between the cartons; with a remote monitoring module, values can be viewed throughout the voyage.

If there is not enough volume to fill a container, the refrigerated LCL option is assessed under separate conditions.

How does Voltim Global support this?

In reefer shipments, Voltim Global runs the port exit, genset supply and the road leg in a single plan; cold chain logistics processes are carried out with partners holding GDP certification. The set temperature and vent value in the booking are matched with the loading instructions and the product specification before loading.

Frequently Asked Questions

Can a reefer container also heat?
Yes. With electric heaters, the units maintain the set temperature even when the outside air is cold. In winter, beverages, paints, pharmaceuticals and freeze-sensitive chemicals heading to Russia or Central Europe can be carried in a reefer set to a value between +5 °C and +20 °C. The rules on floor air circulation and record-keeping apply equally in this use.
What is the difference between a reefer container and a refrigerated trailer?
A reefer container is a container that can be transferred between ship, train and truck; on the road it draws its power from a genset. A refrigerated trailer, on the other hand, is a road vehicle with its own refrigeration unit, and the cargo stays in the same body from door to door. For long journeys with a sea leg the reefer is more practical; for mainly road transport the refrigerated trailer is.
Can a reefer container be used for dry cargo?
Yes, if the shipping line agrees. A reefer carrying dry cargo without the refrigeration unit running is known in the industry as a NOR (non-operating reefer). It is generally offered at an attractive price on routes where reefer containers would otherwise return empty. Its internal volume is smaller than that of a dry container, and the cargo must not damage the inner surfaces or the T-profiles.

Published: 21.11.2026 · Voltim Global