What is a temperature data logger and how is it used in the cold chain?

Last updated:

Short Answer — Temperature Data Logger

A temperature data logger is a small electronic device placed next to or inside the cargo that measures and records temperature at set intervals. In the cold chain, it is the evidence documenting whether the product stayed within the permitted range throughout the shipment. The record is read on delivery; if there is an excursion, its duration and magnitude form the basis for the decision to accept or quarantine the product.

What does a data logger prove?

The display of a reefer trailer shows the air temperature of the refrigeration unit; it does not show the temperature the product experienced. A door opening, incorrect stowage or a pallet that was not pre-cooled can push one corner of the trailer several degrees away from the set point. Because a data logger sits next to the product, it records the actual exposure. For pharmaceuticals, this record is the document showing that the product was transported under the right conditions, as required by Good Distribution Practice (GDP). For quick-frozen food, EU Regulation 37/2005 requires means of transport to be fitted with temperature recorders complying with EN 12830.

What types are there?

TypeHow does it work?Where is it preferred?
Single-useStarted and sent with the shipment; generates a PDF report when plugged into USBOne-way exports, shipments where the consignee does not return the device
Multi-useProgrammed with software, data read out and reset, calibrated periodicallyRegular routes, warehouses and distribution with an own fleet
Real-timeSends location and temperature to the cloud via GSM/LTE, gives instant alarmsHigh-value pharmaceuticals, long road and multimodal shipments
Probe-connectedExternal sensor placed in the product box or a liquid bufferCargo where the product core temperature must be monitored

Because real-time devices also produce location data, they work as part of cargo tracking with IoT sensors.

How is it set up and used?

  1. Range and limits: The product's label condition is entered; for example, 2–8 °C for a refrigerated product and 15–25 °C for a room-temperature product.
  2. Logging interval: 5–15 minutes is common for road shipments. The shorter the interval, the more short door openings become visible, but battery life shortens.
  3. Alarm logic: A single-event alarm (e.g. 30 minutes above 8 °C) and a cumulative alarm (60 minutes in total) can be defined together.
  4. Start delay: A start delay is set so that the device does not count the ambient temperature during loading as an excursion.
  5. Placement: The device is placed at the riskiest point: the pallet by the door, the top tier or a carton near the wall. In a temperature-mapped trailer, this point is known.
  6. Documentation: The device serial number is written on the CMR or the delivery document.

How is the report read on delivery?

The consignee first stops the device and retrieves the report. The fields to check are: do the start and end times match the shipment, the minimum and maximum values, the total time spent outside the limits and the number of alarms. If the curve is flat but above the limit, the unit setting is suspected; if there are sudden peaks, a door opening or transloading is suspected. If there is an excursion, the product is quarantined; suitability for sale is decided, for pharmaceuticals by the responsible person based on the manufacturer's stability data. In a damage claim, the logger report is the main evidence; how the policy treats it depends on whether temperature excursions are insured.

How is data stored under GDP?

  • The EU GDP Guidelines require distribution records to be kept for the period stated in national legislation, and for at least 5 years.
  • Electronic records must be unalterable; the original file and the PDF report should be archived together.
  • Devices are calibrated at intervals determined by risk assessment, against traceable references. The calibration certificate is linked to the report.
  • Excursions are recorded, their root cause is investigated and corrective action is documented.

Common mistakes

  • Placing the device at the air outlet of the refrigeration unit; the record looks better than it really is.
  • Forgetting to start the logger. A blank report means no evidence.
  • Making a GDP shipment with a multi-use device whose calibration has expired.

How does Voltim Global support this?

In cold chain logistics, Voltim Global works with partners holding GDP certificates and links the logger placement, serial number and delivery report to the shipment file. On shipments using real-time devices, the logger readings are reviewed as part of the daily shipment follow-up, alongside the real-time tracking of the driver's location in the customer panel. Pre-cooling the vehicle and keeping the set point throughout the trip are separate control steps of cold chain road transport.

Frequently Asked Questions

Is a separate data logger needed when the reefer trailer has its own recorder?
In most cases, yes. The trailer's recorder measures the air temperature of the refrigeration unit and is the carrier's equipment. The data logger, by contrast, sits next to the product and is used as independent evidence by the shipper or consignee. Presenting both records together in GDP audits and damage claims shortens disputes. The unit record of a reefer trailer usually comes from the return-air and supply-air sensors.
How accurate should a data logger be?
For pharmaceutical and food shipments, an accuracy of ±0.5 °C and a resolution of 0.1 °C are commonly required. For food, EN 12830 divides recorders into accuracy classes. When purchasing, the device's measuring range, battery life, logging capacity and traceable calibration certificate should be assessed together. At low temperatures such as dry ice or deep freezing, an external probe may be needed.