An ISO tank container is a cylindrical tank, usually of stainless steel, mounted inside a standard 20-foot container frame. Liquid chemicals, food-grade liquids and gases are carried in it in bulk, and it is handled like a container on ships, trains and trucks. When carrying dangerous goods, it must comply with the portable tank rules in ADR and the IMDG Code, i.e. the T codes.
The structure of an ISO tank
The tank sits in a steel frame with the dimensions of a 20-foot (6.058 m) ISO container. Thanks to its corner fittings, it is lifted by crane, stacked on ships and carried by road on a container chassis just like other containers. The shell is usually stainless steel; the outside is insulated and clad with aluminium or glass fibre. Typical capacity is 21,000–26,000 litres. There is a filling hatch (manhole) and a pressure relief valve on top and a discharge valve at the bottom; a steam or electric heating jacket can be added for viscous products. A comparison with other container types is in the container types and dimensions entry.
What do the T codes mean?
ADR and the IMDG Code assign a portable tank instruction to every dangerous substance that may be carried in a portable tank. This instruction is shown in column 10 of ADR Table A by a code beginning with the letter T. Instructions T1–T22 define the minimum test pressure, minimum shell thickness, bottom discharge and pressure relief requirements for liquids and solids. T23 is for self-reactive substances and organic peroxides, T50 for non-refrigerated liquefied gases and T75 for refrigerated liquefied gases. A tank complying with a stricter instruction than the one required may also be used.
| Instruction | Minimum test pressure | Bottom discharge opening |
|---|---|---|
| T4 | 2.65 bar | Permitted with additional closure requirement |
| T11 | 6 bar | Permitted with additional closure requirement |
| T14 | 6 bar | Not permitted |
| T20 | 10 bar | Not permitted |
The product is not chosen to fit the tank being hired; the tank is chosen to fit the product: first, the T code in Table A is found using the product's UN number, then it is compared with the approved instruction on the tank plate.
Why does the degree of filling matter?
In a half-full tank, the liquid surges back and forth under braking and wave effects. This mass movement can generate enough force to overturn the tank and the vehicle. ADR 4.2.1.9.6 therefore prohibits filling between more than 20% and less than 80% for liquids with a viscosity below 2,680 mm²/s at 20 °C, unless the tank is divided into compartments of no more than 7,500 litres. The upper limit is calculated by formula according to the liquid's thermal expansion: 97% is taken as the basis in general use and 95% for packing groups I and II of Classes 6.1 and 8, and the expansion allowance is deducted. In practice, the tank is either filled above 80% or the load is planned to stay below 20%.
Cleaning and inspection documents
- Cleaning certificate: After discharge, the tank is washed at an authorised tank cleaning station. In Europe, EFTCO's European Cleaning Document (ECD) is widely used; it shows the previous cargo, the cleaning method and the hatch seals. For a food-grade tank, the list of previous cargoes is decisive for the buyer.
- Periodic inspection: Under ADR 6.7.2.19, the tank is tested before first use and then at least once every five years, with a mandatory 2.5-year intermediate inspection in between. The date of the last test is written on the tank plate.
- CSC plate: Shows the structural safety of the frame as a container.
ISO tank vs flexitank
| Criterion | ISO tank | Flexitank |
|---|---|---|
| Structure | Steel tank inside a frame | Single-use bag placed in a 20' dry container |
| Capacity | Approx. 21,000–26,000 L | Usually 10,000–24,000 L |
| Dangerous goods | Carried with the appropriate T code | Not carried; non-hazardous liquids only |
| Typical cargo | Chemicals, food-grade liquids, gases | Vegetable oil, wine, latex, glycerine |
| Return | Cleaned and reused | The bag is discarded, the container goes back to dry cargo |
How does Voltim Global support this?
As a logistics company with an SQAS (IDS) assessment, Voltim Global checks the tank's T code, cleaning certificate and inspection date before loading in dangerous goods (ADR) and container transport operations.